The Wittkopp PRIMOR 2000 Lev5 is the default lock of the Sintra Forte's vault.
All are shipped with the same default code (123456).
Opening the Lock
- Enter the 6-digit code
If the introduced code is correct, you'll hear 2 short beeps.
Otherwise, if the introduced code is wrong/denied, you'll hear a single longer beep. - Turn the input unit/the lever clockwise within 3 seconds into the opening position.
The lock is opened.
Changing the Codes
The lock allows the programming of a user code alongside the master code.
The master is able to program the user code, but not vice versa.
Programming the user code (programme 1)
- Press and hold the key “1“ until the red LED flashes permanently.
- Enter your 6-digit master code (e.g. 123456).
- Enter the new 6-digit user code (e.g. 111111).
- Re-enter the new 6-digit user code (e.g 111111).
Notes:
- A new user code will be allowed only if the code is differing in two places by a single digit from an existing code.
- Should the new code be denied, restart the process of programming.
Changing the master or user code (programme 0)
- Press and hold the key “0“ until the red LED flashes permanently.
- Enter your old 6-digit code (e.g. user code. 111111)
- Enter your new 6-digit code (e.g. 567891).
- Re-enter your new 6-digit code (e.g. 567891).
Deleting the user (programme 3)
- Press and hold the key “3“ until the red LED flashes permanently.
- Enter your 6-digit master code (e.g. 123456).
Time delay and Opening Window
The lock allows the master user to set values for 'Time delay' and 'Opening window'
Time delay: 01 - 99 minutes - time to wait until the lock can be opened.
Opening window: 01 - 19 minutes - within this time window the master or the user can open the lock with his code.
If the Time delay is active: LED flashes every 10 seconds.
If the Blocking time is active: LED flashes every 2 seconds.
Adjusting the time delay and opening window (programme 9)
- Press and hold the key “9“ until the red LED flashes permanently.
- Enter your 6-digit master code (e.g. 123456).
- Enter the time delay (e.g. 20 minutes).
- Enter the opening window (e.g. 10 minutes).
- Re-enter the time delay (e.g. 20 minutes).
- Re-enter the opening window (e.g. 10 minutes).
Note: The time delay can be increased at any time. It can be reduced only during the opening window.
Opening with activated time delay and opening window
- Enter your 6-digit code (e.g. mastercode. 123456)
- Wait until the end of the time delay.
LED flashes. - Opening window starts.
LED flashes and you hear a beep. - Re-enter your 6-digit code within the opening window (e.g. 123456)
- Turn the input unit/the lever clockwise within 3 seconds into opening position.
The lock is opened.
Deleting the time delay (programme 9)
- Enter your 6-digit code e.g. mastercode. (123456)
- Wait until the end of the time delay.
LED flashes - Opening window starts.
LED flashes and you hear a beep. - Press and hold the key “9“ until the red LED flashes permanently.
- Enter your 6-digit master code (e.g. 123456).
- Delete the time delay. 00
- Delete the opening window. 01
- Delete the time delay again. 00
- Delete the opening window again. 01
Testing the system (programme 5)
Press every number once. A functional key will be confirmed by a double signal. A key that was not identified is confirmed by a long signal and the functional test is aborted. The system has to be checked.
- Press and hold the key “5“ until the red LEDs flash permanently.
- Press every key in its order of appearance. (1234567890)
Power supply and battery change
The lock is power supplied by one 9 V block battery alkaline (no rechargeable batteries!).
When battery voltage is insufficient, after entering the code a warning tone occurs repeatedly and the red LED flashes alternately. Change the battery as quickly as possible.
The programmed codes stay valid during a battery change.